西門子直流調速裝置上電就跳閘-二小時好;SIEMENS維(wei)(wei)(wei)(wei)修(xiu)廠家,上海恒稅電氣有(you)限公(gong)司(si),你的(de)選擇沒有(you)錯。公(gong)司(si)自成立以來,長期銷售維(wei)(wei)(wei)(wei)修(xiu)西門子(zi)變頻器(qi)(qi)及伺服驅動器(qi)(qi)的(de),觸摸屏,PLC,直流調速器(qi)(qi)等,積累了豐富的(de)維(wei)(wei)(wei)(wei)修(xiu)經驗,對所(suo)維(wei)(wei)(wei)(wei)修(xiu)的(de)機(ji)器(qi)(qi)建立完(wan)善的(de)維(wei)(wei)(wei)(wei)修(xiu)檔案,所(suo)有(you)我們(men)維(wei)(wei)(wei)(wei)修(xiu)的(de)機(ji)器(qi)(qi)我們(men)都有(you)完(wan)善的(de)參數備(bei)份,確(que)保我們(men)維(wei)(wei)(wei)(wei)修(xiu)的(de)機(ji)器(qi)(qi)上機(ji)即能使用。
西門子直流調速裝置上電就跳閘-二小時好;
維修(xiu)起來可就沒那么(me)順(shun)利了。先是(shi)(shi)維修(xiu)開(kai)關電(dian)(dian)(dian)(dian)(dian)源,主要元件無(wu)一(yi)幸免,通(tong)電(dian)(dian)(dian)(dian)(dian)試機后發(fa)(fa)現檢(jian)測(ce)比較器(qi)(qi)(qi)全部冒(mao)煙(yan),更換后測(ce)量+24V,+15V,-15V,+5V均已修(xiu)復,接主板(ban)(ban)后顯示(shi)屏不(bu)(bu)亮,面板(ban)(ban)指示(shi)燈長亮,測(ce)量主板(ban)(ban)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya)正(zheng)常,CPU嚴重(zhong)發(fa)(fa)熱(re)(re),只好(hao)更換主板(ban)(ban)。更換主板(ban)(ban)后接通(tong)220V工作(zuo)電(dian)(dian)(dian)(dian)(dian)源,顯示(shi)CALIBRATION FAIL校(xiao)準失敗,然后約(yue)半分鐘(zhong)后觸發(fa)(fa)板(ban)(ban)100歐(ou)(ou)電(dian)(dian)(dian)(dian)(dian)阻冒(mao)煙(yan),正(zheng)常情況下直流(liu)調速器(qi)(qi)(qi)這(zhe)個(ge)(ge)(ge)時候應該要顯示(shi)正(zheng)常,不(bu)(bu)發(fa)(fa)熱(re)(re)不(bu)(bu)報警(jing)的(de), 清理線路后結果如下,主板(ban)(ban)觸發(fa)(fa)芯片2003輸(shu)出(chu)導通(tong)信號,經過(guo)電(dian)(dian)(dian)(dian)(dian)源板(ban)(ban)的(de)十二顆標記053的(de)三(san)極管(NPN,基極觸發(fa)(fa)后將(jiang)集(ji)電(dian)(dian)(dian)(dian)(dian)極對(dui)地,集(ji)電(dian)(dian)(dian)(dian)(dian)極接的(de)是(shi)(shi)脈沖(chong)(chong)變(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)的(de)一(yi)個(ge)(ge)(ge)引(yin)(yin)腳(jiao),另一(yi)個(ge)(ge)(ge)引(yin)(yin)腳(jiao)通(tong)過(guo)100歐(ou)(ou)電(dian)(dian)(dian)(dian)(dian)阻接通(tong)24伏),放大導通(tong)脈沖(chong)(chong)變(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi),跟功放輸(shu)出(chu)繼(ji)電(dian)(dian)(dian)(dian)(dian)器(qi)(qi)(qi)一(yi)個(ge)(ge)(ge)控制方式(shi)。可逆(ni)式(shi)電(dian)(dian)(dian)(dian)(dian)源板(ban)(ban)插(cha)座排列:兩(liang)端共(gong)8個(ge)(ge)(ge)引(yin)(yin)腳(jiao)是(shi)(shi)+24V,中間(jian)兩(liang)排共(gong)12個(ge)(ge)(ge)引(yin)(yin)腳(jiao)為(wei)觸發(fa)(fa)脈沖(chong)(chong),不(bu)(bu)可逆(ni)小插(cha)座:右側4個(ge)(ge)(ge)引(yin)(yin)腳(jiao)為(wei)+24V,左(zuo)側6個(ge)(ge)(ge)引(yin)(yin)腳(jiao)為(wei)脈沖(chong)(chong)。發(fa)(fa)熱(re)(re)冒(mao)煙(yan)的(de)原因是(shi)(shi)其中一(yi)跟三(san)極管短路,相當開(kai)脈沖(chong)(chong)變(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)初級得到了24V直流(liu)電(dian)(dian)(dian)(dian)(dian)壓(ya)(ya)(ya),所以限流(liu)電(dian)(dian)(dian)(dian)(dian)阻會(hui)過(guo)熱(re)(re)冒(mao)煙(yan)。
將三(san)極管更換后(hou)試(shi)機,顯示器(qi)(qi)報(bao)警ACCTS 故障(zhang)(ACCTS FAILED),故障(zhang)報(bao)警意思為(wei)電(dian)(dian)(dian)流傳感器(qi)(qi)異(yi)常(chang),但是此時三(san)個(ge)(ge)電(dian)(dian)(dian)流傳感器(qi)(qi)都已經接好,線(xian)路也(ye)沒(mei)有開路,三(san)個(ge)(ge)電(dian)(dian)(dian)流傳感器(qi)(qi)有三(san)個(ge)(ge)引腳(jiao)相連,另外(wai)三(san)個(ge)(ge)引腳(jiao)送到藍(lan)色主板(ban)插頭旁邊的(de)六只二極管形成三(san)相橋式整(zheng)流,通過LM324比較(jiao)檢(jian)測。更換LM324后(hou)ACCTS FAILED故障(zhang)消(xiao)失。開關變壓器(qi)(qi)上邊三(san)個(ge)(ge)指(zhi)示燈:FLD HS OT ,ARM HS OT ,PHASE LOSS,分(fen)別(bie)是勵磁超(chao)溫(wen)(wen),電(dian)(dian)(dian)樞超(chao)溫(wen)(wen),三(san)相電(dian)(dian)(dian)平低(di)報(bao)警。當(dang)兩個(ge)(ge)溫(wen)(wen)度(du)燈異(yi)常(chang)點亮時測試(shi)方法:溫(wen)(wen)度(du)線(xian)插頭外(wai)的(de)兩顆圓形貼(tie)片電(dian)(dian)(dian)阻100歐兩端分(fen)別(bie)對地,1001(1K)方形貼(tie)片電(dian)(dian)(dian)阻為(wei)檢(jian)測腳(jiao),此時如果兩個(ge)(ge)溫(wen)(wen)度(du)燈還(huan)異(yi)常(chang)亮起(qi),說明檢(jian)測電(dian)(dian)(dian)路壞了(le)。
西門子直流調速裝置上電就跳閘-二小時好;西門子6RA70直流(liu)調速(su)器的弱磁設置完(wan)事方法。
1 . 系統設(she)定值復位及偏差調(diao)整
?? 用(yong)(yong)PMU 執(zhi)行功能P051= 21,或在PC 中調用(yong)(yong)缺省的工廠設置參數構成基本
參(can)數(shu)文件,凡是(shi)下(xia)文中未提到的參(can)數(shu)都利(li)用缺省參(can)數(shu),參(can)數(shu)值見手冊,用
P052=0 顯示那些(xie)與初始工廠設置不同的(de)參數。
?? 合(he)上裝(zhuang)置控(kong)制電源(yuan)和操作控(kong)制電源(yuan)執行P051=21,偏差(cha)調整(zheng)(P051=22)同時
進行,參(can)數P825.02 被設置。
2 . 整 流 裝 置 參 數 設 定
?? P067=1-5 選擇(ze)負載過負荷周期,見手冊,當本參(can)數大于1 時,整流(liu)器(qi)額定
2
直流電流R072.01 將變為所選周期內(nei)的基本負載(zai)值(zhi),P075 參數必須設定為
1 或2。一般情況下,裝置的計算的晶(jing)閘管溫(wen)升(sheng)包容(rong)上(shang)述過載周期
?? P075=0 不允(yun)許裝(zhuang)置過載, 裝(zhuang)置最(zui)大輸出電(dian)流被限制(zhi)在額定直(zhi)流電(dian)流
R072.01
?? =1 電樞電流(liu)(liu)(liu)最大(da)值被限制(zhi)在P077*1.8*整(zheng)流(liu)(liu)(liu)器(qi)額定直流(liu)(liu)(liu)電流(liu)(liu)(liu)R072.01,當計
算的晶(jing)閘管溫升超過允許值時,報警A039 激活,電(dian)樞(shu)電(dian)流(liu)給(gei)定(ding)自(zi)動自(zi)動減
小到整流(liu)器(qi)額定電(dian)流(liu)R072.01。
?? =2 整流(liu)器電樞電流(liu)最大值被限(xian)制在 P077*1.8* 整流(liu)器額定直流(liu)電流(liu)
R072.01,當(dang)計算的晶閘管溫升超過允(yun)許值時,故障F039 被激(ji)活。
?? 本參數根據電機額定(ding)參數值和使用工況,從保護(hu)裝置過(guo)載的角度出發進行設(she)
置,本(ben)參數與P067 共同作(zuo)用,對(dui)裝置的過負荷周期進行(xing)設定。
?? P078.01= 630V 主回(hui)路進線(xian)交流電(dian)壓(ya),作(zuo)為(wei)判斷電(dian)壓(ya)故障的基(ji)準值
?? P078.02= 380V,勵磁進線電壓
?? 作為(wei)欠壓或過壓的(de)判斷門(men)檻電壓,相關參數(shu)見(jian)P351,P352,P361-P364.
3 . 電機(ji)參數設(she)定
?? P100(F)= 額(e)定電動機電樞電流(A)
?? P101(F)=額定電動機電樞(shu)電壓(V)
?? P102(F)= 額定電(dian)動機勵(li)磁電(dian)流(A)
?? P103(F)=最(zui)小電機勵磁(ci)電流(A),必須小于(yu) P102 的50%.在弱磁(ci)調速場合(he),一
般設定到(dao)防止失磁的數值.