西(xi)門(men)(men)子(zi)伺服電(dian)機報F31150(編(bian)碼器損壞);上海恒(heng)稅電(dian)氣維(wei)修(xiu)公司10年(nian)專(zhuan)注(zhu)于西(xi)門(men)(men)子(zi)自動(dong)化設(she)備(bei)(bei)維(wei)修(xiu)銷(xiao)售,擁有西(xi)門(men)(men)子(zi)全套測試平臺,另外倉庫配件充足,維(wei)修(xiu)帶載運行可以(yi)快速可靠的檢測設(she)備(bei)(bei)故障點位,專(zhuan)業維(wei)修(xiu),上機測試正常后提供給客戶(hu), 使(shi)(shi)設(she)備(bei)(bei)能達到現(xian)場正常使(shi)(shi)用。為用戶(hu)節約(yue)時(shi)間成本、提高生產效率(lv)!
西門子伺服電機報F31150(編碼器損壞)故障分析解決;
1.伺服控制器(qi)中(zhong)編(bian)碼(ma)器(qi)的(de)設(she)置不對,修改參(can)數(shu)。
2.信(xin)號干擾,改(gai)善接地(di)與屏蔽。
3.電機(ji)軸承(cheng)損壞,維修電機(ji)。
4.編碼器或編碼器電纜損(sun)壞(huai),更換。
5.伺服控制器編(bian)碼(ma)器接口(kou)損壞或接觸不良,維修。
一般(ban)來(lai)說,只(zhi)要電(dian)機使(shi)用(yong)正(zheng)(zheng)確(que),維護(hu)(hu)得當,發現故障及時處理(li),電(dian)機的工作(zuo)壽(shou)命是很長(chang)的。為了(le)保(bao)證電(dian)機正(zheng)(zheng)常(chang)(chang)工作(zuo),除(chu)了(le)按(an)操作(zuo)規程正(zheng)(zheng)常(chang)(chang)使(shi)用(yong)、運行過(guo)程中注意(yi)正(zheng)(zheng)常(chang)(chang)監(jian)視和維護(hu)(hu)外,還應該進(jin)行定期(qi)檢(jian)查(cha),做(zuo)好電(dian)機維護(hu)(hu)保(bao)養工作(zuo)。下面小(xiao)編給大家整(zheng)理(li)以下幾點(dian)關于電(dian)機定期(qi)維護(hu)(hu)注意(yi)事項供(gong)大家參(can)考。
電機定(ding)期維護注意事項(xiang):
1、清(qing)擦電機(ji)。及時清(qing)除電機(ji)機(ji)座(zuo)外(wai)部的灰(hui)塵、油(you)泥。如(ru)使(shi)用環境(jing)灰(hui)塵較多,每(mei)天清(qing)掃(sao)一次(ci)。
2、檢(jian)查和清擦電機接(jie)線(xian)端子。檢(jian)查接(jie)線(xian)盒(he)接(jie)線(xian)螺絲是否(fou)松動、燒(shao)傷。
3、檢查各固(gu)定(ding)部分螺(luo)絲(si)(si),包括地腳螺(luo)絲(si)(si)、端(duan)蓋螺(luo)絲(si)(si)、軸承蓋螺(luo)絲(si)(si)等。將松動的(de)螺(luo)母擰緊。
4、檢(jian)查(cha)傳動裝(zhuang)置(zhi)、檢(jian)查(cha)皮帶輪或聯(lian)軸器(qi)有無魄力、損(sun)壞,安裝(zhuang)是(shi)否牢固;皮帶及其聯(lian)結扣(kou)是(shi)否完好。
5、電機的啟動設備,也要(yao)及時清擦(ca)外部(bu)(bu)灰塵(chen)、你夠,擦(ca)拭觸頭,檢查各接線(xian)部(bu)(bu)位是否有燒(shao)傷痕跡,接地線(xian)是否良好。
6、軸(zhou)承的檢查(cha)與(yu)維(wei)護。軸(zhou)承在使用一(yi)段(duan)時間后應(ying)(ying)該(gai)清(qing)(qing)洗(xi),更(geng)換(huan)(huan)潤(run)(run)滑脂或(huo)(huo)潤(run)(run)滑油(you)(you)。清(qing)(qing)洗(xi)和換(huan)(huan)油(you)(you)的時間,應(ying)(ying)隨電機的工(gong)(gong)作(zuo)情況,工(gong)(gong)作(zuo)環境,清(qing)(qing)潔程度,潤(run)(run)滑劑種類而定,一(yi)半每工(gong)(gong)作(zuo)3-6個月,應(ying)(ying)該(gai)清(qing)(qing)洗(xi)一(yi)次,重新(xin)換(huan)(huan)潤(run)(run)滑脂。油(you)(you)溫較(jiao)高時,或(huo)(huo)者環境條件差、灰塵(chen)較(jiao)多的電機要經常清(qing)(qing)洗(xi)、換(huan)(huan)油(you)(you)。
西門子伺服電機報F31150(編碼器損壞)故障分析解決;其(qi)他故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang)解決(jue)包括;,F30001,F36200,F07800,F30897,F23004,380500,過流,超溫,欠(qian)壓,RDY燈閃爍(shuo),燈不亮,亮紅燈,伺(si)服未準備就緒,復位(wei)(wei)使能,軸Z1伺(si)服故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang),功(gong)率(lv)部件(jian)過載維(wei)修(xiu),驅(qu)動(dong)對(dui)象不可以運(yun)行(xing),從動(dong)裝(zhuang)置故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang),201315,DP03,4065故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang),緩沖存儲器故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang),數(shu)據(ju)丟失故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang),400015故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang)維(wei)修(xiu),profibus-DP 邏輯地址(zhi)故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang),BUS總線故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang),F0650*維(wei)修(xiu),F01001故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang),F01205故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang),F06000,F30027代碼維(wei)修(xiu),380500維(wei)修(xiu),復位(wei)(wei)不掉維(wei)修(xiu),西門子交流伺(si)服電機(ji)維(wei)修(xiu),F0793*維(wei)修(xiu),F01030報警(jing)維(wei)修(xiu),F07412換(huan)向角出錯,F30027欠(qian)壓故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang)維(wei)修(xiu),F07930剎車故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang)維(wei)修(xiu),F01030控(kong)制(zhi)權下(xia)的生命符號出錯,231116代碼,025201軸X1驅(qu)動(dong),231116報警(jing),循環數(shu)據(ju)傳送故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang),231885,軸X1伺(si)服故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang),207016電機(ji)溫度傳感器故(gu)(gu)(gu)(gu)障(zhang)(zhang)(zhang)(zhang),230021,025201,700015,700028,F31129編(bian)碼器信(xin)號偏(pian)差。